     Non-detectable acid and alkali-resistant safety warning tape for the protection, location, and identification of underground utility installations. Consists of a minimum 4.0 mil (0.004") overall thickness, inert 100% virgin low density polyethylene plastic film formulated for extended use underground. Tape shall be specified and supplied in accordance with the A.P.W.A. national color code and shall be permanently imprinted in black, environmentally safe, ink with an appropriate legend to define the type of utility line it protects. Linemark is impregnated with color-fast, lead-free, organic pigments suitable for direct burial and prolonged exposure to the elements normally encountered in the earth's soils.
II. TEST DATA
PROPERTY METHOD VALUE
Thickness ASTM D 2103 4.0 mils
Tensile Strength ASTM D 882 10.6 lbs/inch of width
-MD 2660 PSI
-TD 2590 PSI
Elongation ASTM D882-75B 500% Average
-MD 410%
-TD 580%
Impact Resistance ASTM D 1709; Method A 288 grams
Printability ASTM D 2578 >40 dynes/cm2
Standard Specification ASTM D 2103-86 1,3,3,2,1
Flexibility ASTM D 671-76 pliable hand
Inks Mfgr. Specs. heat set mylex
Message Repeat Mfgr. Specs. every 20 inches
Composition Mfgr. Specs. virgin LLDPE/LDPE
Colors APWA Code see next page
III. APPROVALS
A. Department of Transportation Bureau, Office of Pipeline Safety-USAS code for pressure piping B31.8 paragraph 192.321 (e).
B. National Transportation Safety Board, Washington D. C., Special Study Prevention of Damage to Pipelines, Adopted June 7, 1973-Report NTSB-PSS-73-1.
C.American Petroleum Institute (API), Recommended practice for making buried liquid petroleum pipelines-API RP 1109.
D. General Services Administration, Washington D.C., Public Buildings Service Guide Specification for Mechanical and Electrical Equipment-PBS 4-1501, Amendment 2, page 1501-14, paragraph 18, sub paragraph 18.1, clause 18.1.1.
E. Rural Electrification Authority (REA), U.S. Dept. of Agriculture, Washington, D.C., National Electrical Safety Code for Underground Construction for remote and immediate hazards.
IV. COLOR CODE
  • Safety Red
  • -Electric power, distribution & transmission, and municipal electric systems.
  • High Visibility Safety Yellow
  • -Gas & oil distribution & transmission, dangerous materials, product & steam.
  • Safety Alert Orangeli>-Telephone and Telegraph systems, police and fire communications, and cable television.
  • Safety Precaution Blue
  • -Water systems and slurry pipelines.
  • Safety Green
  • -Sanitary and storm sewer systems.
    Customer Service Phone Numbers
    Toll Free Voice (800) 627-5255
    Toll Free Fax (800) 889-3147
    Local Voice (817) 457-8753
    Local Fax (817) 451-0637
    E-mail csr@craftmarkid.com
    Business Hours
    Monday-Friday 8:00 AM CST to 5:00 PM CST
    Map
    US Headquarters
    3212 S. Cravens Rd.P.O. Box 50668
    Fort Worth, TX 76119Fort Worth, TX 76105
    Credit Cards Accepted:
    Read and Review Craftmark's Limit of Liability Statement.
    copyright © 2005 CRAFTMARK FT. WORTH, TX - All Rights Reserved