Craftmark Identification Products

Detectamark Detectable Underground
Tape Technical Data Page

View the PDF File
A PRODUCT OF CRAFTMARK
DETECTAMARK DETECTABLE UNDERGROUND UTILITY MARKING TAPE
SPECIFICATIONS, TEST DATA, APPROVALS AND COLOR CODE
I. SPECIFICATIONS
     Consists of a minimum 5.0 mil (0.005")overall thickness, with no less than 35 gauge (0.00035") solid aluminum foil core. The foil must be visible from both sides and the adhesives that bond the protective plastic jacket to both sides of the foil must be applied directly to the film and foil layer with NO inks or printing extending to the edges of the tape. The adhesive will NOT contain any dilutants, pigments, or contaminants and is especially formulated to resist degradation by elements in the soil. All printing shall be encased to avoid ink rub-off.
II. TEST DATA
PROPERTY METHOD VALUE
Thickness ASTM D 2103 5.0 mils
Tensile Strength ASTM D 882 25 lbs/inch (5500 psi)
Elongation ASTM D 882-75B <50% @ break
Printability ASTM D 2578 >40 dynes/cm2
Flexibilty ASTM D 671-76 pliable hand
Inks Mfgr. Specs heat set Mylex
Message Repeat Mfgr. Specs every 20 inches
Foil Mfgr. Specs. deadsoft/anealled
Top Layer Mfgr. Specs. virgin PET
Bottom Layer Mfgr. Specs. virgin LDPE
Adhesives Mfgr. Specs. >30% solid, 1.5#/R
Bond Strength Boiling H20 100o >5 hours w/o peel
Colors APWA Code see next page
III. APPROVALS
A. Department of Transportation Bureau, Office of Pipeline Safety-USAS code for pressure piping B31.8 paragraph 192.321 (e).
B. National Transportation Safety Board, Washington D. C., Special Study Prevention of Damage to Pipelines, Adopted June 7, 1973-Report NTSB-PSS-73-1.
C.American Petroleum Institute (API), Recommended practice for making buried liquid petroleum pipelines-API RP 1109.
D. General Services Administration, Washington D.C., Public Buildings Service Guide Specification for Mechanical and Electrical Equipment-PBS 4-1501, Amendment 2, page 1501-14, paragraph 18, sub paragraph 18.1, clause 18.1.1.
E. Rural Electrification Authority (REA), U.S. Dept. of Agriculture, Washington, D.C., National Electrical Safety Code for Underground Construction for remote and immediate hazards.
IV. COLOR CODE
  • Safety Red
  • -Electric power, distribution & transmission, and municipal electric systems.
  • High Visibility Safety Yellow
  • -Gas & oil distribution & transmission, dangerous materials, product & steam.
  • Safety Alert Orangeli>-Telephone and Telegraph systems, police and fire communications, and cable television.
  • Safety Precaution Blue
  • -Water systems and slurry pipelines.
  • Safety Green
  • -Sanitary and storm sewer systems.
  • Safety Brown
  • -Force mains, reclaimed water lines, and effluent re-ues lines
  • Alert Purple
  • -Reclaimed non-potable water lines.
    Customer Service Phone Numbers
    Toll Free Voice (800) 627-5255
    Toll Free Fax (800) 889-3147
    Local Voice (817) 457-8753
    Local Fax (817) 451-0637
    E-mail csr@craftmarkid.com
    Business Hours
    Monday-Friday 8:00 AM CST to 5:00 PM CST
    Map
    US Headquarters
    3212 S. Cravens Rd.P.O. Box 50668
    Fort Worth, TX 76119Fort Worth, TX 76105
    Credit Cards Accepted:
    Read and Review Craftmark's Limit of Liability Statement.
    copyright © 2005 CRAFTMARK FT. WORTH, TX - All Rights Reserved